Kidde KN-COSM-IB Hardwire Combination Carbon Monoxide and Smoke Alarm with

Kidde KN-COSM-IB Hardwire Combination Carbon Monoxide and Smoke Alarm with Battery Backup and Voice Warning, Interconnectable
Price : $34.53
List Price : $61.99
You Save : $27.46 (44%)
Kidde KN-COSM-IB Hardwire Combination Carbon Monoxide and Smoke Alarm with Battery Backup and Voice Warning, Interconnectable

Item Description


Amazon.com Item Description
The KN-COSM-IB combines a Carbon Monoxide and Ionization Smoke Alarm, offering two essential security devices in a single unit. This alarm contains a voice warning system that helps get rid of confusion, as it tells you if its detected fire or carbon monoxide, or even if it wants a new battery. This alarm has 9 volt battery backup, which protects you and your family members - even through a power outage when countless incidences occur. The alarm also permits you to quickly silence nuisance alarms employing its handy Wise Hush function. This talking combo alarm is powered by your home’s electricity and can interconnect with other smoke alarms in your property. Professionals advise interconnected alarms, for the reason that when a single sounds, they all sound, offering an early warning against fire by drastically escalating your capacity to hear an alarm anyplace in your household, regardless of where the fire begins.
Kidde KN-COSM-IB Hardwire Mixture Smoke and CO Alarmwith 9V Battery Backup
  • Employs each smoke andcarbon monoxide sensors.
  • Inter-connectable to give improved protection
  • Attributes a hush button to silence the alarm for non-emergency conditions like a smoky dinner.


Protects from two distinctive hazards, smoke and carbon monoxide. .
Gives the recommended protection of an interconnected system. When one alarm goes off, they all do. .
Offers the recommended protection of an interconnected technique. When a single alarm goes off, they all do. .
Mixture Smoke/CO Alarm for Improved SafetyThe Kidde Combination Carbon Monoxide Smoke Alarm consists of a voice warning system that eliminates confusion and clearly warns you and your family members of a smoke or carbon monoxide danger, or if your battery is in want of replacement or your alarm is in hush mode.
Alarm Warnings Fire: The red LED will flash and be accompanied by 3 extended alarm beeps followed by a verbal warning message “Fire! Fire!” The alarm will repeat pattern until smoke is eliminated.
Carbon Monoxide: 4 short alarm beeps followed by a verbal warning “Warning! Carbon Monoxide!” This continues till the unit is reset or CO is eliminated.
Low Battery: One particular chirp followed by warning “Low Battery” The red LED light will flash. This pattern will continue just about every minute for the initially hour. Just after the initial hour the red LED light will flash once each and every minute accompanied by the chirp sound. The low battery warning will only sound as soon as every fifteen minutes.
Voice Hush Indication: “Hush Activated” and “Hush Cancelled” voice announcement
Peak Level Memory: If the alarm had detected a CO level of 100ppm or higher when the Test/Reset button is pressed, the unit will announce “Carbon Monoxide Previously Detected” to warn of the CO incident.

Inter-connectable for Enhanced SafetyFire and consumer authorities suggest interconnected alarms for added protection. According to the National Fire Protection Association (NFPA), most Americans really feel they are far more at danger of getting a victim of a tornado than of a home fire. Basically the opposite is true. Fires are even more popular than any other disaster that strikes a family members at house, and can turn out to be deadly in minutes.
You have on average much less than 3 minutes from the time you hear a smoke alarm to escape a fire. The sooner you hear an alarm, the sooner you can get out safely. Smoke alarms that link together so that when a single goes off, they all go off, are known as interconnected alarms. These alarms provide alot more warnings in additional places, giving your household far more time to escape a home fire. Houses built soon after 1993 are required by developing codes to have interconnected alarms that are wired into their electrical method.

Trademarked Hush Function for ConvenienceBy pressing the Hush button, you can easily and safely silence nuisance alarms brought on by non-emergency scenarios, such as overcooked dinners.
This function desensitizes the alarm for around ten minutes. If the smoke is not too dense, the alarm will silence quickly, the unit will verbally announce “Hush Mode Activated,” and the green LED will flash each and every two seconds for approximately 10 minutes.

Trustworthy 9-Volt Battery Backup, Indicator LED, Test Feature, Low Battery and End-of-Life Warning
The alarm’s 9-volt battery backup supplies continuous protection, even for the duration of power outages. Since this alarm only helps defend you if it really is operating, this unit characteristics a red LED that flashes each and every 30 to 40 seconds to indicate that it is operating properly. For additional peace of thoughts, the alarm also consists of a test/reset button that enables you to periodically test its circuitry and horn.
If any form of battery failure is detected the red LED light will flash and the unit will “chirp” one particular time, followed by the warning message “Low Battery.” This cycle will take place when every single minute, and will continue for at least seven days.
Seven (7) years following initial power up, this unit will “chirp”every 30 seconds. This is an “operational finish of life” function which will indicate that it is time to replace the alarm. UL 2034, the independent typical applicable to CO alarms, needs CO alarms to have an end of life warning. This requirement went into effect in March 2007, meaning any CO alarm manufactured following April 2007 with a UL listing must have this feature. Most states that demand CO alarms in residential dwellings mandate that the alarm meet the UL 2034 regular.
The unit measures just 5.75 inches in diameter and 1.7 inches deep, and it characteristics a neutral, white finish. It includes tamper resist attributes to deter vandalism or theft. This combination smoke/CO alarm is UL listed, so you can be confident of its high quality, and it is backed by a five-year restricted warranty.

About Kidde: A UTC Fire Safety Brand Renowned for worldwide leadership in fire detection and suppression, Kidde provides solutions ranging from portable fire extinguishers to advanced industrial controls such as flame detection and explosion suppression systems. Kidde is a UTC Fire Security brand, with a history that’s rich with innovations, from the patent of the Chubb Detector Lock in 1818 to the development of the world's very first wireless networked smoke detectors in 2004.

What's in the BoxCombination smoke and carbon monoxide alarm with mounting bracket and mounting hardware, fast-connect wiring harness, 1 9 volt battery, a five-year limited warranty and a bilingual (English/Spanish) user's manual.

From the Manufacturer
The top lead to of accidental poisoning deaths in North America, Carbon Monoxide is odorless, tasteless and invisible. It is a silent killer. Kidde CO alarms include the most correct sensing technology obtainable, the patented Nighthawk electrochemical sensor. This unit combines a Carbon Monoxide and Ionization Smoke Alarm, supplying two vital security devices in a single unit. This alarm consists of a voice warning system that announces "Fire, Carbon Monoxide, Low Battery or Smart Hush Activation." The voice alarm eliminates any confusion and clearly warns you and your family of a smoke or carbon monoxide danger, or if your battery is in will need of replacement. This unit is hardwired and will function with quite a few interconnected systems. This combination alarm has battery backup, safeguarding you and your loved ones even for the duration of a power outage when various incidences happen. Install at least one particular CO alarm on each floor and in sleeping regions. Make confident CO and Smoke alarms are at least 15 feet away from cooking or heating appliances to prevent false alarms. Replace CO alarms just about every five to 7 years to benefit from the most current technologies upgrades. Ionization sensing alarms might possibly detect invisible fire particles connected with rapid flaming fires sooner than Photoelectric alarms. Research show each types will properly detect either sort of fire. For optimal protection, install both smoke alarm technologies in your home.
Kidde KN-COSM-IB Hardwire Combination Carbon Monoxide and Smoke Alarm with Battery Backup and Voice Warning, Interconnectable